Posted on May 2, 2019

ASTM E1980 PDF

ASTM E Is the American Society for Testing and Materials document titled, “ Standard Practice for Calculating Solar Reflectance Index of Horizontal and. ASTM Standards for Measuring Solar Reflectance and Infrared. Emittance of Construction Materials and Comparing their. Steady-State Surface Temperatures. 1, ASTM E specifications. 2. 3, Quantity, Name, Value, Units. 4, Solar reflectance of black surface, RB, 5, Solar reflectance of white surface, RW,

Author: Arashimi Kigagore
Country: Belize
Language: English (Spanish)
Genre: Finance
Published (Last): 23 June 2004
Pages: 344
PDF File Size: 17.69 Mb
ePub File Size: 16.35 Mb
ISBN: 980-9-59229-853-8
Downloads: 21363
Price: Free* [*Free Regsitration Required]
Uploader: Shakajin

Retrieved June 3,from http: Heat island effect — roof.

Solar reflectance and thermal emittance are important factors affecting surface and near-surface ambient air temperature. It is defined so that a standard black surface reflectance 0. Da Vinci 11 Bizkaia – Zamudio.

Ed Bizkaia – Zamudio. Surface Optics does not perform aged SRI testing. Green Building Council Many roofing manufacturers have already obtained independent laboratory testing of the SRI of their product catalog.

Table 2 shows the requirements for hardscape and shade providing architectural devices and structures. Heat Island Effect — Non-Roof and 7. The SRI makes it possible for finishes to be categorised based on their capacity to reduce the urban heat island effect.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Surfaces with low solar reflectance, absorb a high fraction of the incoming solar energy. Referenced Documents purchase separately The documents listed below are referenced within the subject s1980 but are not provided as part of the standard. For equivalent conditions, the lower the emissivity of a surface the higher its e1908 temperature.

  BURSZTA WOJCIECH ANTROPOLOGIA KULTURY PDF

Green Building CouncilOctober 4. Through a system of international agreements, the results issued by a laboratory accredited by ENAC are recognised in over 70 countries around the world.

No other units of measurement are included in this standard.

Legal information Privacy Policy Accessibility. Access to home page of website. Related Videos More videos. Download PDF 8,49 Mb. Astondo Bidea, Edificio To satisfy the requirements of the Heat Island reduction credits, a certain percentage of the hardscape and roofing must have a high solar reflectance index.

The method described here gives the SRI of surfaces based on measured solar reflectances and thermal emissivities of the surfaces. Determination of solar reflectance and thermal emittance, and subsequent calculation of the relative temperature of the surfaces with respect to black and white reference temperature defined as Solar Reflectance Index, SRImay help designers and consumers to choose the proper materials to make their buildings and communities energy efficient.

As a consequence, we strive to broaden the scope of accreditation year after year to include the new tests required in the industry. This accreditation is the result of a clear commitment to remain at the forefront of technical solutions in optical characterisation, and to provide such service for our customers.

Historical Version s – view previous versions of standard. Go to main menu of page. Link to Active This link will always route to the current Active version of the standard. Jump to main contents of current page. The SRI value makes it possible for finishes to be categorised based on their capacity to reduce the urban heat island effect.

  ALEXANDER STEPANOV ELEMENTS OF PROGRAMMING PDF

Solar Reflectance Index Measurements – Surface Optics Corp.

By calculating the SRImanufacturers of building products are able improve the properties of the finishes, develop new products that comply with the requirements set out in the certification, and consequently, better position their products on the market.

Retrieved May 29,from http: Combined Sustainable Sites credits 7. Direct Normal and Hemispherical on 37 Tilted Surface. Surfaces with low emissivity cannot effectively radiate to the sky and, therefore, get hot.

A fraction of this absorbed energy is conducted into ground and buildings, a fraction is convected to air leading to higher air temperaturesand a fraction is radiated to the sky. Our e1908 will provide a report that includes the values shown in Table 1 for the provided sample s.

ASTM E1980 – 11

Your desired roofing or hardscape SRI specifications may be readily available in the form of a manufacturer datasheet which can be used as LEED documentation.

The method is intended to calculate SRI for surfaces with emissivity greater than 0. It also helps other agents such as architects, builders, and building owners and managers to choose suitable materials and finishes that contribute to reducing surface temperatures, thereby reducing the energy consumption of the buildings.

The impact of hardscape such as roads, sidewalks, courtyards, and parking lots is an important element in earning the Heat Island reduction credit.